Record ID | marc_columbia/Columbia-extract-20221130-024.mrc:102758740:14003 |
Source | marc_columbia |
Download Link | /show-records/marc_columbia/Columbia-extract-20221130-024.mrc:102758740:14003?format=raw |
LEADER: 14003cam a2200517Mi 4500
001 11664280
005 20160223142608.0
008 150817s2015 nyua u 001 0 eng
020 $a125958612X
020 $a9781259586125
020 $z1259586138 (electronic bk)
020 $z9781259586132 (electronic bk)
035 $a(OCoLC)ocn927136594
035 $a(OCoLC)927136594
035 $a(NNC)11664280
040 $aAU@$beng$cAU@$erda$dOCLCO$dMNM
090 $aTH420$b.T46 2015
100 1 $aThornburg, Douglas W.,$eauthor.
245 10 $a2015 International Building Code Illustrated Handbook /$cDouglas W. Thornburg, John R. Henry.
264 1 $aNew York$bMcGraw-Hill Education,$c[2015]
264 4 $c©2015
300 $axx, 969 pages :$billustrations ;$c24 cm
336 $atext$2rdacontent
337 $aunmediated$2rdamedia
338 $avolume$2rdacarrier
500 $aIncludes index.
505 0 $aMachine generated contents note: Section 101 General -- Section 102 Applicability -- Section 103 Department of Building Safety -- Section 104 Duties and Powers of Building Official -- Section 105 Permits -- Section 107 Submittal Documents -- Section 108 Temporary Structures and Uses -- Section 109 Fees -- Section 110 Inspections -- Section 111 Certificate of Occupancy -- Section 112 Service Utilities -- Section 113 Board of Appeals -- Section 114 Violations -- Section 115 Stop Work Order -- Section 116 Unsafe Structures and Equipment -- Key Points -- Section 201 General -- Section 202 Definitions -- Key Points -- Section 302 Classification -- Section 303 Assembly Group A -- Section 304 Business Group B -- Section 305 Educational Group E -- Section 306 Factory Group F -- Section 307 High-Hazard Group H -- Section 308 Institutional Group I -- Section 309 Mercantile Group M -- Section 310 Residential Group R -- Section 311 Storage Group S --
505 0 $aNote continued: Section 312 Utility and Miscellaneous Group U -- Key Points -- Section 402 Covered Mall and Open Mall Buildings -- Section 403 High-Rise Buildings -- Section 404 Atriums -- Section 405 Underground Buildings -- Section 406 Motor-Vehicle-Related Occupancies -- Section 407 Group 1-2 -- Section 408 Group 1-3 -- Section 409 Motion-Picture Projection Rooms -- Section 410 Stages, Platforms, and Technical Production Areas -- Section 411 Special Amusement Buildings -- Section 412 Aircraft-Related Occupancies -- Section 413 Combustible Storage -- Section 414 Hazardous Materials -- Section 415 Groups H-1, H-2, H-3, H-4, and H-5 -- Section 416 Application of Flammable Finishes -- Section 417 Drying Rooms -- Section 418 Organic Coatings -- Section 419 Live/Work Units -- Section 420 Groups I-1, R-1, R-2, R-3, and R-4 -- Section 422 Ambulatory Care Facilities -- Section 423 Storm Shelters -- Section 424 Children's Play Structures -- Key Points -- Section 501 General --
505 0 $aNote continued: Section 503 General Building Height and Area Limitations -- Section 504 Building Height and Number of Stories -- Section 505 Mezzanines and Equipment Platforms -- Section 506 Building Area -- Section 507 Unlimited-Area Buildings -- Section 508 Mixed Use and Occupancy -- Section 509 Incidental Uses -- Section 510 Special Provisions -- Key Points -- Section 602 Construction Classification -- Section 603 Combustible Material in Type I and II Construction -- Key Points -- Section 703 Fire-Resistance Ratings and Fire Tests -- Section 704 Fire-Resistance Rating of Structural Members -- Section 705 Exterior Walls -- Section 706 Fire Walls -- Section 707 Fire Barriers -- Section 708 Fire Partitions -- Section 709 Smoke Barriers -- Section 710 Smoke Partitions -- Section 711 Floor and Roof Assemblies -- Section 712 Vertical Openings -- Section 713 Shaft Enclosures -- Section 714 Penetrations -- Section 715 Joint Systems -- Section 716 Opening Protectives --
505 0 $aNote continued: Section 717 Ducts and Air Transfer Openings -- Section 718 Concealed Spaces -- Section 719 Fire-Resistance Requirements for Plaster -- Section 720 Thermal- and Sound- Insulating Materials -- Section 721 Prescriptive Fire Resistance -- Section 722 Calculated Fire Resistance -- Key Points -- Section 801 General -- Section 803 Wall and Ceiling Finishes -- Section 804 Interior Floor Finish -- Section 805 Combustible Materials in Types I and II Construction -- Key Points -- Section 901 General -- Section 903 Automatic Sprinkler Systems -- Section 904 Alternative Automatic Fire-Extinguishing Systems -- Section 905 Standpipe Systems -- Section 907 Fire Alarm and Detection Systems -- Section 909 Smoke-Control Systems -- Section 910 Smoke and Heat Removal -- Section 911 Fire Command Center -- Section 914 Emergency Responder Safety Features -- Key Points -- Section 1001 Administration -- Section 1002 Definitions -- Section 1003 General Means of Egress --
505 0 $aNote continued: Section 1004 Occupant Load -- Section 1005 Means of Egress Sizing -- Section 1006 Number of Exits and Exit Access Doorways -- Section 1007 Exit and Exit Access Doorway Configuration -- Section 1008 Means of Egress Illumination -- Section 1009 Accessible Means of Egress -- Section 1010 Doors, Gates, and Turnstiles -- Section 1011 Stairways -- Section 1012 Ramps -- Section 1013 Exit Signs -- Section 1014 Handrails -- Section 1015 Guards -- Section 1016 Exit Access -- Section 1017 Exit Access Travel Distance -- Section 1018 Aisles -- Section 1019 Exit Access Stairways and Ramps -- Section 1020 Corridors -- Section 1021 Egress Balconies -- Section 1022 Exits -- Section 1023 Interior Exit Stairways and Ramps -- Section 1024 Exit Passageways -- Section 1025 Luminous Egress Path Markings -- Section 1026 Horizontal Exits -- Section 1027 Exterior Exit Stairways and Ramps -- Section 1028 Exit Discharge -- Section 1029 Assembly --
505 0 $aNote continued: Section 1030 Emergency Escape and Rescue -- Key Points -- Section 1101 General -- Section 1102 Definitions -- Section 1103 Scoping Requirements -- Section 1104 Accessible Route -- Section 1105 Accessible Entrances -- Section 1106 Parking and Passenger Loading Facilities -- Section 1107 Dwelling Units and Sleeping Units -- Section 1108 Special Occupancies -- Section 1109 Other Features and Facilities -- Section 1110 Recreational Facilities -- Section 1111 Signage -- Key Points -- Section 1203 Ventilation -- Section 1204 Temperature Control -- Section 1205 Lighting -- Section 1206 Yards or Courts -- Section 1207 Sound Transmission -- Section 1208 Interior Space Dimensions -- Section 1209 Access to Unoccupied Spaces -- Section 1210 Toilet and Bathroom Requirements -- Key Points -- Section 1402 Definitions -- Section 1403 Performance Requirements -- Section 1404 Materials -- Section 1405 Installation of Wall Coverings --
505 0 $aNote continued: Section 1406 Combustible Materials on the Exterior Side of Exterior Walls -- Section 1407 Metal Composite Materials -- Section 1408 Exterior Insulation and Finish Systems (EIFS) -- Key Points -- Section 1502 Definitions -- Section 1504 Performance Requirements -- Section 1505 Fire Classification -- Section 1506 Materials -- Section 1510 Rooftop Structures -- Key Points -- Introduction to the Structural Provisions -- Structural Design (Chapter 16): Nonseismic -- Structural Design (Chapter 16): Seismic -- Structural Design (Chapter 16): Load Combinations -- Introduction -- Section 1601 General -- Section 1602 Definitions and Notations -- Section 1603 Construction Documents -- Section 1604 General Design Requirements -- Section 1605 Load Combinations -- Section 1606 Dead Loads -- Section 1607 Live Loads -- Section 1608 Snow Loads -- Section 1609 Wind Loads -- Section 1610 Soil Lateral Loads -- Section 1611 Rain Loads -- Section 1612 Flood Loads --
505 0 $aNote continued: Section 1613 Earthquake Loads -- Section 1614 Atmospheric Ice Loads -- Section 1615 Structural Integrity -- Key Points -- Example 16-1 Design Axial Force, Shear Force, and Bending Moment for Shear Wall Due to Lateral and Gravity Loads (Strength Design) -- Example 16-2 Design Axial Force, Shear Force, and Bending Moment for Shear Wall Due to Lateral and Gravity Loads (Allowable Stress Design Using Basic Load Combinations) -- Example 16-3 Design Axial Force, Shear Force, and Bending Moment for Shear Wall Due to Lateral and Gravity Loads (Allowable Stress Design Using Alternate Basic Load Combinations) -- Example 16-4 Calculations of Live Load Reduction -- Introduction -- Section 1701 General -- Section 1702 Definitions -- Section 1703 Approvals -- Section 1704 Special Inspections and Tests, Contractor Responsibility, and Structural Observations -- Section 1705 Required Special Inspections and Tests -- Section 1706 Design Strengths of Materials --
505 0 $aNote continued: Section 1707 Alternate Test Procedures -- Section 1708 In Situ Load Tests -- Section 1709 Preconstruction Load Tests -- Key Points -- Introduction -- Section 1801 General -- Section 1802 Definitions -- Section 1803 Geotechnical Investigations -- Section 1804 Excavation, Grading, and Fill -- Section 1805 Dampproofing and Waterproofing -- Section 1806 Presumptive Load-Bearing Values of Soils -- Section 1807 Foundation Walls, Retaining Walls, and Embedded Posts and Poles -- Section 1808 Foundations -- Section 1809 Shallow Foundations -- Section 1810 Deep Foundations -- Key Points -- Introduction -- Section 1901 General -- Section 1902 Definitions -- Section 1903 Specifications for Tests and Materials -- Section 1904 Durability Requirements -- Section 1905 Modifications to ACI 318 -- Section 1906 Structural Plain Concrete -- Section 1907 Minimum Slab Provisions -- Section 1908 Shotcrete -- Key Points -- Introduction -- Section 2002 Materials -- Key Points --
505 0 $aNote continued: Introduction -- Section 2101 General -- Section 2102 Definitions and Notations -- Section 2103 Masonry Construction Materials -- Section 2104 Construction -- Section 2105 Quality Assurance -- Section 2106 Seismic Design -- Section 2107 Allowable Stress Design -- Section 2108 Strength Design of Masonry -- Section 2109 Empirical Design of Masonry -- Section 2110 Glass Unit Masonry -- Section 2111 Masonry Fireplaces -- Section 2112 Masonry Heaters -- Section 2113 Masonry Chimneys -- Key Points -- Introduction -- Section 2201 General -- Section 2202 Definitions -- Section 2203 Identification and Protection of Steel for Structural Purposes -- Section 2204 Connections -- Section 2205 Structural Steel -- Section 2206 Composite Structural Steel and Concrete Structures -- Section 2207 Steel Joists -- Section 2208 Steel Cable Structures -- Section 2209 Steel Storage Racks -- Section 2210 Cold-Formed Steel --
505 0 $aNote continued: Section 2211 Cold-Formed Steel Light-Framed Construction -- Key Points -- Introduction -- Section 2301 General -- Section 2302 Definitions -- Section 2303 Minimum Standards and Quality -- Section 2304 General Construction Requirements -- Section 2305 General Design Requirements for Lateral-Force-Resisting Systems -- Section 2306 Allowable Stress Design -- Section 2307 Load and Resistance Factor Design -- Section 2308 Conventional Light-Frame Construction -- Section 2309 Wood Frame Construction Manual -- Key Points -- Section 2403 General Requirements for Glass -- Section 2404 Wind, Snow, Seismic, and Dead Loads on Glass -- Section 2405 Sloped Glazing and Skylights -- Section 2406 Safety Glazing -- Section 2407 Glass in Handrails and Guards -- Section 2408 Glazing in Athletic Facilities -- Key Points -- Section 2501 Scope -- Section 2502 Definitions -- Section 2508 Gypsum Construction -- Section 2510 Lathing and Furring for Cement Plaster (Stucco) --
505 0 $aNote continued: Section 2511 Interior Plaster -- Section 2512 Exterior Plaster -- Key Points -- Section 2603 Foam Plastic Insulation -- Section 2604 Interior Finish and Trim -- Section 2605 Plastic Veneer -- Section 2606 Light-Transmitting Plastics -- Section 2607 Light-Transmitting Plastic Wall Panels -- Section 2608 Light-Transmitting Plastic Glazing -- Section 2609 Light-Transmitting Plastic Roof Panels -- Section 2610 Light-Transmitting Plastic Skylight Glazing -- Key Points -- Section 2702 Emergency and Standby Power Systems -- Section 2902 Minimum Plumbing Facilities -- Key Points -- Section 3002 Hoistway Enclosures -- Section 3003 Emergency Operations -- Section 3006 Elevator Lobbies and Hoistway Opening Protection -- Section 3007 Fire Service Access Elevator -- Section 3008 Occupant Evacuation Elevators -- Key Points -- Section 3102 Membrane Structures -- Section 3104 Pedestrian Walkways and Tunnels -- Section 3106 Marquees -- Key Points --
505 0 $aNote continued: Section 3201 General -- Section 3202 Encroachments -- Section 3302 Construction Safeguards -- Section 3303 Demolition -- Section 3304 Site Work -- Section 3306 Protection of Pedestrians -- Section 3307 Protection of Adjoining Property -- Section 3308 Temporary Use of Streets, Alleys and Public Property -- Section 3309 Fire Extinguishers -- Section 3310 Means of Egress -- Section 3311 Standpipes -- Key Points -- Appendix A Employee Qualifications -- Appendix B Board of Appeals -- Appendix C Group U Agricultural Buildings -- Appendix D Fire Districts -- Appendix E Supplementary Accessibility Requirements -- Appendix F Rodentproofing -- Appendix G Flood-Resistant Construction -- Appendix H Signs -- Appendix I Patio Covers -- Appendix J Grading -- Appendix K Administrative Provisions -- Appendix L Earthquake Recording Instrumentation -- Appendix M Tsunami-Generated Flood Hazard -- Metric Units, System International (SI) -- Soft Metrication --
500 $aContents note continued: Hard Metrication.
650 0 $aBuilding laws.
650 0 $aConstruction industry$xStandards.
650 0 $aArchitecture$xStandards.
700 1 $aHenry, John R.$q(John Randolph),$d1948-$eauthor.
710 2 $aInternational Code Council,$eissuing body.
852 00 $bavelc$hTH420$i.T46 2015g