It looks like you're offline.
Open Library logo
additional options menu

MARC Record from Library of Congress

Record ID marc_loc_2016/BooksAll.2016.part40.utf8:262678184:2795
Source Library of Congress
Download Link /show-records/marc_loc_2016/BooksAll.2016.part40.utf8:262678184:2795?format=raw

LEADER: 02795cam a2200349 i 4500
001 2013045571
003 DLC
005 20150109081334.0
008 131113t20142014flua b 001 0 eng
010 $a 2013045571
020 $a9781439881309 (hardback)
020 $a1439881308 (hardback)
040 $aDLC$beng$cDLC$erda$dDLC
042 $apcc
050 00 $aTK2821$b.E34 2014
082 00 $a621.31/042$223
084 $aTEC008000$aTEC008010$2bisacsh
245 00 $aElectrical contacts :$bprinciples and applications /$cedited by Paul G. Slade.
250 $aSecond edition.
264 1 $aBoca Raton :$bCRC Press, Taylor & Francis Group,$c[2014]
264 4 $c©2014
300 $axliv, 1268 pages :$billustrations ;$c27 cm.
336 $atext$2rdacontent
337 $aunmediated$2rdamedia
338 $avolume$2rdacarrier
520 $a"Preface to the Second Edition Since the publication of the first edition of this book there have been some very costly system failures, which could have been prevented with a better knowledge of electrical contact phenomena. I will give two examples. The first is an electrical connector that supplied power to the "Main Fuel Shut-off Valve" in the F-16 fighter airplane. This connector used tin plated pins plugged into a gold plated socket. As will be briefly discussed in Chapters 3 and 4, the failure of this combination from fretting corrosion in the aircraft's vibration environment caused the fuel to stop flowing to the jet engines. Several F-16 crashes are attributed to this connector failure with a subsequent cost of over $100 M. In hindsight it is probable that this pin socket combination used extensively in the earlier F-111 airplane resulted in it cancellation. Failure of the connectors most probably resulted in this plane's performance changing from a "terrain following" aircraft to a "terrain impacting" one. The second example occurred in the Large Hadron Collider (LHC), which began its initial testing in September 2008. Soon after it began to operate, a connection to a 12 MVA transformer failed. This cut power to the main compressors that operated the cryogenic system for cooling the super conducting magnets in two sections. This failure caused extensive wiring damage that cost more than $20 M to repair and set back the initial operation of this expensive experimental system by about nine months"--$cProvided by publisher.
504 $aIncludes bibliographical references and index.
650 0 $aElectric contacts.
650 7 $aTECHNOLOGY & ENGINEERING / Electronics / General.$2bisacsh
650 7 $aTECHNOLOGY & ENGINEERING / Electronics / Circuits / General.$2bisacsh
700 1 $aSlade, Paul G.,$d1941-
856 42 $3Cover image$uhttp://images.tandf.co.uk/common/jackets/websmall/978143988/9781439881309.jpg