Calculations of solar water collector hourly thermal energy output as part of central solar water heating system with individual 150 liters storage tanks for each apartment in high rise multi-apartment residential building in Tel Aviv.
The energy output at noon is 758 kcal/hr in January and 1,221 kcal/hr in April.
Solar collectors supply 2,647 kWh/year of thermal energy to each apartment, minimum 5.41 kWh/day on an average day in December, maximum 8.53 kWh/day in August.
Hot water supply equivalent at 40°C is 30 liter/hr in December and 81 liter/hr in August at noon, 192 liter/day in January to 500 liter/day in August.
Buy this book
Subjects
Solar Collector, Solar Water Collector, SWH, Solar Water Heater, Domestic Hot Water, SDWH, Solar Domestic Water Heater, Solar Energy, Solar Energy in Buildings, Renewable Energy, Water Heating, Energy in Buildings, Solar Energy Calculations, Building Energy, Multi-Apartment Buildings, Residential BuildingsPlaces
Tel AvivTimes
2021Edition | Availability |
---|---|
1
Solar Water Collector Hourly Energy Output: Central Solar Water Heaters, Multi-Apartment Residential Buildings in Tel Aviv